19 DATA LOGGING FUNCTION
19.5 Details of Specifications
Specifying the monitored data
For monitored data, the following devices can be specified. The data types that can be selected include bit/word (unsigned),
word (signed), double word (unsigned), and double word (signed).
*1 Index modification, and indirect specification cannot be specified.
*2 For bit devices, bit specification of word cannot be specified.
*3 For word devices, nibble specification of bit devices cannot be specified.
*4 To specify these devices with the CPU Module Logging Configuration Tool, use T (contact): TS, ST (contact): STS, C (contact): CS, LC
(contact): LCS.
*5 Applicable only to FX5U/FX5UC CPU module.
*6 To specify these devices with the CPU Module Logging Configuration Tool, use T (current value): T or TN, ST (current value): ST or
STN, C (current value): C or CN, and LC (current value): LC or LCN.
*7 This format is supported by the FX5UJ and FX5U/FX5UC CPU modules.
Target data
This section describes the data to be collected by data logging.
Number of data points
The data logging function can collect up to 512 data records. (4 settings 128 records)
*1
*1 Duplicate data records are counted as unique records.
Data to be collected
The data for the following devices can be specified to be collected.
*1 Index modification, and indirect specification cannot be specified.
*2 For bit devices, bit specification of word cannot be specified.
*3 For word devices, nibble specification of bit devices cannot be specified.
*4 To specify these devices with the CPU Module Logging Configuration Tool, use T (contact): TS, T (coil): TC, ST (contact): STS, ST (coil):
STC, C (contact): CS, C (coil): CC, LC (contact): LCS, and LC (coil): LCC.
*5 Applicable only to FX5U/FX5UC CPU module.
*6 To specify these devices with the CPU Module Logging Configuration Tool, use T (current value): T or TN, ST (current value): ST or
STN, C (current value): C or CN, and LC (current value): LC or LCN.
*7 This format is supported by the FX5UJ and FX5U/FX5UC CPU modules.
Type Device
*1
Bit device
*2
X, Y, M, SM, L, B, F, SB, T (contact)
*4
, ST (contact)
*4
, C (contact)
*4
, LC (contact)
*4
, BL\S
*5
Word device
*3
T (Current value)
*6
, ST (Current value)
*6
, C (Current value)
*6
, D, SD, W, SW, R, U\G
*7
Double-word device LC (current value)
*6
Type Device
*1
Bit device
*2
X, Y, M, SM, L, B, F, SB, T (contact)
*4
, T (coil)
*4
, ST (contact)
*4
, ST (coil)
*4
, C (contact)
*4
, C (coil)
*4
, LC (contact)
*4
, LC (coil)
*4
, BL\S
*5
Word device
*3
T (Current value)
*6
, ST (Current value)
*6
, C (Current value)
*6
, D, SD, W, SW, R, U\G
*7
Double-word device LC (current value)
*6