362
29 POSITIONING CONTROL FUNCTION
29.3 Positioning Control
Interrupt stop
1-speed positioning is performed by the table operation instruction. (Page 360 1-speed positioning) When the interruption
input signal 1 is detected during pulse output operation, the operation decelerates and stops. (Page 395 Interrupt Input
Signal 1) Both relative address and absolute address can be used for the interrupt stop.
The following table shows applicable control methods of the table operation.
*1 Only CPU module is supported.
Precautions
When the interrupt input signal 1 does not turn on, the operation is the same as the 1-speed positioning.
Positioning instruction Table operation control method
Table operation (TBL
*1
/DRVTBL/DRVMUL) instruction 6: Interrupt Stop (Relative Address Specification)
7: Interrupt Stop (Absolute Address Specification)
Acceleration
time
Deceleration
time
Maximum speed
Command
speed
Bias speed
Current position
Stop position Positioning address
Interrupt
input signal 1