19 DATA LOGGING FUNCTION
19.5 Details of Specifications
177
19
<Data type information row>
The data type for each column is displayed. This information is output in the following format: (Data type)[(Additional
information)].
Ex.
The size of the data type information row is determined by the following equation when data logging of 128 points of data
(signed 16-bit integer, decimal format) is performed (The following sections in the "Output" window are set to be output: "Date"
(the output format is YYYY/MM/DD hh:mm:ss.sss), "Data sampling interval", and "Index").
(8 + 25) (date column) + 8 (data collection interval column) + 5 (index column) + (5 + 7) 128 (data column) + 132 (the
number of commas) + 2 (CR + LF)
= 1716 bytes
<Data name row>
The data name for each column is displayed.
Ex.
The size of the data name row is determined by the following equation when data logging of 128 data points from D100 to
D227 is performed (The following sections in the "Output" window are set to be output: "Date", "Data sampling interval", and
"Index").
4 (date column) + 12 (data collection interval column) + 5 (index column) + (4 128) (data column) + 132 (the number of
commas) + 2 (CR + LF)
= 667 bytes
Item "Data type" output content Size "Additional information" output content Size
Date column DATETIME 8 bytes Format is output.
[YYYY/MM/DD hh:mm:ss.sss]
4 to 29 bytes
Data collection interval
column
INTERVAL 8 bytes No additional information 0 byte
Index column INDEX 5 bytes No additional information 0 byte
Data column Bit type: BIT 3 bytes Bit type: [1;0] 5 bytes
16-bit integer (signed): SHORT 5 bytes For decimal format: [DEC.0] 7 bytes
16-bit integer (unsigned): USHORT 6 bytes For hexadecimal format: [HEX] 5 bytes
32-bit integer (signed): LONG 4 bytes When the decimal fraction format is specified: [DEC.
(number of digits of decimal part)]
7 to 8 bytes
32-bit integer (unsigned): ULONG 5 bytes
Single-precision floating point (32-bit):
FLOAT
5 bytes When the exponential format is specified: [EXP. (number
of digits of decimal part)]
7 to 8 bytes
Character string type: STRING 6 bytes Character string type, numeric string type: the specified
data length value (unit: bytes) is output.
3 to 5 bytes
Numeric string type: RAW 3 bytes
Time: TIME 4 bytes No additional information 0 byte
Trigger occurrence
information column
TRIGGER 7 bytes [(string occurred)] is output (semicolons (;), double
quotation marks (" "), and commas (,) cannot be used).
3 to 514 bytes
Item Description Size
Date column TIME (time zone) is output. 4 bytes
Data collection interval column INTERVAL[us] is output. 12 bytes
Index column INDEX is output. 5 bytes
Data column The specified device name is output. 1 to 32 bytes
Trigger occurrence information column Trigger is output. 7 bytes