25 HIGH-SPEED INPUT/OUTPUT FUNCTION
25.1 High-speed Counter Function
261
25
Multiple point output, high-speed comparison table operation
Operation of each type high-speed comparison table is explained below.
Bit output
When comparison value 1 matches the current value of the set high-speed counter, output data is transferred to the output
devices.
Ex.
Bit output, initial output device: Y0, Output points: 16
Word output
When comparison value 1 matches the current value of the set high-speed counter, output data is transferred to the output
devices.
Ex.
Word output, initial output device: D0, Output points: 1
Table number Comparison value Output data
Table 1 10 H0001
Table 2 13 HAAAA
Table 3 19 H0100
Table number Comparison value Output data
Table 1 10 K100
Table 2 13 K300
Table 3 19 K10
Y0Y1Y2Y3Y4Y5Y6Y7Y10Y11Y12Y13Y14Y15Y16Y17
0000000 000
1 00000
01
1 1 1 1 0 1 0 1 0 10000
0000000000000001
0000000000000000
Current value 0 to 9
Y0Y1Y2Y3Y4Y5Y6Y7Y10Y11Y12Y13Y14Y15Y16Y17
Current value 10 to 12
Y0Y1Y2Y3Y4Y5Y6Y7Y10Y11Y12Y13Y14Y15Y16Y17
Current value 13 to 18
Y0Y1Y2Y3Y4Y5Y6Y7Y10Y11Y12Y13Y14Y15Y16Y17
Current value 19 to
Current value 0 to 9
D0 = 0
Current value 10 to 12
D0 = 100
Current value 13 to 18
D0 = 300
Current value 19 to
D0 = 10