EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-F FX5 - Page 321

Mitsubishi Electric MELSEC iQ-F FX5
958 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25 HIGH-SPEED INPUT/OUTPUT FUNCTION
25.4 Pulse Catch Function
319
25
Displayed items
High-speed pulse input/output module
Add the high-speed pulse input/output module.
High-speed pulse input/output module is supported for FX5UJ/FX5U/FX5UC CPU modules.
Navigation window [Parameter] [Module Information] Right-click Add New Module
After adding the high-speed pulse input/output module, make settings on the screen displayed from the following operation.
Navigation window [Parameter] [Module Information] [1 to 16 (high-speed pulse input/output module)]
[Module Parameter] "Input Function" "General/Interrupt/Pulse Catch" "Detailed Setting"
Window
Shown above is the screen at the time when the first high-speed pulse input/output module is selected.
Displayed items
Parameters are enabled when the CPU module is powered ON or after a reset.
Item Description Setting range Default
General/Interrupt/Pulse
Catch
Set the function to be used.
Set to "Interrupt (Rising) + Pulse Catch".
General-purpose Input
Interrupt (Rising)
Interrupt (Falling)
Interrupt (Rising + Falling)
Interrupt (Rising) + Pulse Catch
General-purpose
Input
Item Description Setting range Default
General/Interrupt/Pulse
Catch
Set the function to be used.
Set to "Interrupt (Rising) + Pulse Catch".
General-purpose Input
Interrupt (Rising)
Interrupt (Falling)
Interrupt (Rising + Falling)
Interrupt (Rising) + Pulse Catch
General-purpose
Input
Interrupt Pointer Set the interrupt pointer (I) which is assigned to each input.
The pulse catch function does not use an interrupt pointer.
I50 to I177

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-F FX5

Related product manuals