30 POSITIONING PARAMETER
30.2 Details of Parameters
387
30
Position Data Magnification
Setting method: High Speed I/O Parameter
The values of positioning addresses can be multiplied by the Position Data Magnification. The available multiplying factors
include single, 10 times, 100 times, and 1000 times. The following shows a setting example.
Ex.
For magnification by 1000 times
For the positioning address of 123, the following shows the actual address and transfer distance.
Motor System unit: 123 10
3
= 123000 [pulse]
Machine/Multiple System unit: 123 10
3
= 123000 [m, 10
-4
inch, mdeg] = 123 [mm, 10
-1
inch, deg]
The following table lists the relation between the positioning data magnification of each unit system.
Position Data
Magnification
Unit system setting (position unit) Unit system setting (speed unit)
pulse m 0.0001 inch mdeg pps cm/min inch/min 10 deg/min
Single pulse m 0.0001 inch mdeg pps cm/min inch/min 10 deg/min
10 times 10 pulse 10 m 0.001 inch 10 mdeg
100 times 100 pulse 100 m 0.01 inch 100 mdeg
1000 times 1000 pulse mm 0.1 inch deg