30 POSITIONING PARAMETER
30.2 Details of Parameters
391
30
Deceleration Time
Setting method: High Speed I/O Parameter, Special Device
Set the time required for deceleration from the maximum speed to the bias speed.
The setting range of deceleration time is 0 to 32767 ms. If command speed is slower than the maximum speed, the actual
deceleration time becomes shorter than the set time.
■Special Device
When deceleration time is set to 0, deceleration is not performed. Because the motor stops immediately, the machine may be
damaged.
Name CPU module High-speed pulse input/output module R/W
First module Second module Third module Fourth module
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8 Axis 9 Axis 10 Axis 11 Axis 12
Deceleration time SD5521 SD5561 SD5601 SD5641 SD5681 SD5721 SD5761 SD5801 SD5841 SD5881 SD5921 SD5961 R/W
R/W: Read/Write