31 POSITIONING INSTRUCTION
31.2 Pulse Y Output
427
31
Operand specification
When FX5 operand is specified
1. For (s), specify the command speed. Set to a value 0 to 200 kpps in pulse. For the FX5S CPU module, set to a value 0 to
100 kpps.
PLSY: 0 to 65535 (User system unit)
DPLSY: 0 to 2147483647 (User system unit)
2. For (n), specify the positioning address. (Page 392 Positioning address) Set to a value 0 to 2147483647 in pulse.
PLSY: 0 to 65535 (User system unit)
DPLSY: 0 to 2147483647 (User system unit)
3. For (d), specify an axis number for which pulses are output.
Specify an axis number whose positioning parameters are set in the high speed I/O parameters. Operation cannot be
performed if any other axis number is specified.
FX5S/FX5U/FX5UC CPU module: K1 to K4 (Axis 1 to Axis 4)
FX5UJ CPU module: K1 to K3 (Axis 1 to Axis 3)
When the FX3 compatible operand is specified
1. For (s), specify the command speed. Set to a value 0 to 200 kpps in pulse. For the FX5S CPU module, set to a value 0 to
100 kpps.
PLSY: 0 to 65535 (User system unit)
DPLSY: 0 to 2147483647 (User system unit)
2. For (n), specify the positioning address. Set to a value 0 to 2147483647 in pulse.
PLSY: 0 to 65535 (User system unit)
DPLSY: 0 to 2147483647 (User system unit)
3. For (d), specify the pulse output number.
Specify an output device (Y) number set in the high speed I/O parameters. (Page 382 Pulse Output Mode) Operation
cannot be performed if any other axis number is specified.
FX5S/FX5U/FX5UC CPU module: Y0 to Y3 (equivalent to axes 1 to 4)
FX5UJ CPU module: Y0 to Y2 (equivalent to axes 1 to 3)
Direction handling
The PLSY/DPLSY instruction always increases the current address because the setting of rotation direction is disabled due
to the absence of direction. (Page 384 Rotation Direction Setting)
When the output mode is CW/CCW mode, output is always performed from the device set to CW. (Page 382 Pulse
Output Mode)
If reverse limit is used, it operates as forward limit.