710
APPX
Appendix 1 Special Relay List
SM8051 I1 interrupt disabled (Input interrupt) OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8052 I2 interrupt disabled (Input interrupt) OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8053 I3 interrupt disabled (Input interrupt) OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8054 I4 interrupt disabled (Input interrupt) OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8055 I5 interrupt disabled (Input interrupt) OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8056 I28 interrupt disabled (Interrupt from internal
timer)
OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8057 I29 interrupt disabled (Interrupt from internal
timer)
OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8058 I30 interrupt disabled (Interrupt from internal
timer)
OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8059 I16 to I23 interrupt disabled (High-speed
comparison match interrupt)
OFF: Interrupt enabled
ON: Interrupt disabled
R/W
SM8063 Serial communication error 1 (CH1) OFF: No error
ON: Error
R
SM8067 Operation error OFF: No error
ON: Error
R
SM8068 Operation error latch OFF: No error
ON: Error (latch)
R
SM8072 Parallel link operation OFF: Stopped
ON: In normal running state
R
SM8090 Block comparison signal Block comparison signal ON when all
comparison results are ON.
R
SM8099 High-speed ring counter OFF: High-speed ring counter stop
ON: High-speed ring counter start
R/W
SM8126 Global ON (CH1) Turns ON when the global command is
received.
R
SM8151 Inverter communication (CH1) ON during inverter communication. R
SM8152 Inverter communication error (CH1) OFF: No error
ON: Error
R
SM8153 Inverter communication error latch (CH1) OFF: No error
ON: Error (latch)
R
SM8154 IVBWR instruction error (CH1) OFF: No error
ON: Error
R
SM8156 Inverter communication (CH2) ON during inverter communication. R
SM8157 Inverter communication error (CH2) OFF: No error
ON: Error
R
SM8158 Inverter communication error latch (CH2) OFF: No error
ON: Error (latch)
R
SM8159 IVBWR instruction error (CH2) OFF: No error
ON: Error
R
S
M8161 8 bit operation mode OFF: 16 bit operation mode
ON: 8 bit operation mode
R/W
SM8168 SMOV data mode BINBCD conversion will not be performed, if a
SMOV instruction is executed after turning on
SM8168.
R/W
SM8170 X0 pulse catch Pulse catch ON when X0 is OFFON R/W
SM8171 X1 pulse catch Pulse catch ON when X1 is OFFON R/W
SM8172 X2 pulse catch Pulse catch ON when X2 is OFFON R/W
SM8173 X3 pulse catch Pulse catch ON when X3 is OFFON R/W
SM8174 X4 pulse catch Pulse catch ON when X4 is OFFON R/W
SM8175 X5 pulse catch Pulse catch ON when X5 is OFFON. R/W