APPX
Appendix 2 Special Register List
771
A
SD10808 Connection No.4 received data verification result
(receive packet No.7)
Stores the verification results of receive packet
No.7.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10809 Connection No.4 received data verification result
(receive packet No.8)
Stores the verification results of receive packet
No.8.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10810 Connection No.4 received data verification result
(receive packet No.9)
Stores the verification results of receive packet
No.9.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10811 Connection No.4 received data verification result
(receive packet No.10)
Stores the verification results of receive packet
No.10.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10812 Connection No.4 received data verification result
(receive packet No.11)
Stores the verification results of receive packet
No.11.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10813 Connection No.4 received data verification result
(receive packet No.12)
Stores the verification results of receive packet
No.12.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10814 Connection No.4 received data verification result
(receive packet No.13)
Stores the verification results of receive packet
No.13.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10815 Connection No.4 received data verification result
(receive packet No.14)
Stores the verification results of receive packet
No.14.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10816 Connection No.4 received data verification result
(receive packet No.15)
Stores the verification results of receive packet
No.15.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10817 Connection No.4 received data verification result
(receive packet No.16)
Stores the verification results of receive packet
No.16.
Element No. where the verification result did not
match (b0 to b7)
The cause of mismatch (verification result code)
(b8 to b15)
R
SD10818 Connection No.4 protocol execution count Stores the number of protocol executions in
connection No.4.
0: Protocol not executed
1 to 65535: Number of executions
R
No. Name Description Compatible CPU module R/W