852
APPX
Appendix 7 Processing Time
The following table lists the coefficient values for each processing time.
Item Coefficient value
FX5U/FX5UC CPU module
Program capacity setting:
64000 steps
Program capacity setting:
128000 steps
(a) Active block processing time coefficient 2.6 s2.6 s
(b) Inactive block processing time coefficient 1.2 s1.2 s
(c) Nonexistent block processing time coefficient 0.5 s0.5 s
(d) Active step processing time coefficient FX3 Compatible Transition
Operation Mode Enable
5.8 s8.2 s
FX3 Compatible Transition
Operation Mode Disable
5.4 s7.7 s
(e) Active transition processing time coefficient 2.5 s5.6 s
(f) Transition
establishment step
processing time
coefficient
Hold step FX3 Compatible Transition
Operation Mode Enable
21.9 s28.1 s
FX3 Compatible Transition
Operation Mode Disable
12.3 s13.1 s
Normal step FX3 Compatible Transition
Operation Mode Enable
22.9 s29.2 s
FX3 Compatible Transition
Operation Mode Disable
17.6 s22.1 s
(g) SFC END processing time 2.4 s2.4 s
(h) Operation output processing time coefficient 