CHAPTER 9 DEDICATED INSTRUCTIONS
9
9.5 JP/GP.WRITE (Data Write to Programmable Controllers on Other Stations)
Specify devices of the target station's CPU within the range allowed for the own station CPU when writing data to the
devices with the WRITE instruction.
(Target station's start device (D1) to which data are written) + (Write points - 1) (End device No. of own station's CPU
*1
)
*1 End device No. of the device in the own station CPU, and whose device name is same as (D1)
Specify the own station's start device (D1) within the range allowed for storing write data
Use the file register (ZR) when specifying the extended data register (D) or extended link register (W) that is outside the
area of the own station CPU's data register (D) or link register (W). (Except for the Universal model QCPU)
For the calculation of the file register (ZR), refer to the following.
When D150 and after the area in the own station's CPU has been already used
User's Manual (Function Explanation, Program Fundamentals) for the CPU module used
When 0K point is assigned to the data register (D) of another station (Example) When 0K point is assigned to the
data register (D) of another station CPU, and when all 32K points of the file register (ZR) are assigned to the
extended data register (D)
Ex.
Good example (D50 is specified to (D1).) Bad example (D100 is specified to (D1).)
D50
D0
D99
D0
D99
100 words100 words
D100
D150
D199
D149
D150
Own station CPU Other station CPU Own station CPU Other station CPU
: Data to be written with WRITE instruction
: Area already used by target station's CPU
: Duplicated area
Ex.
ZR12288
ZR12287
ZR0
Own station CPU
*1
Data register
Other station CPU
Extended
data register
*1 A file register whose capacity is 32K points or more is required for the own station's CPU.
ZR32767
Specify with D0 to 12287.
Specify with ZR12288 to 32767.
D12287
D12288
D32767
D0
D12287
D0