356
(S1)+5 Target station No.
Specify the station No. of the target station.
(1) Station No. specification
When own station is Universal model QCPU: 1 to 120
When own station is other than Universal model QCPUs: 1 to
64
To increase the reliability of data, it is recommended to execute
the instruction with the Execution/Error completion type
((S1)+0) set to "1: With arrival confirmation".
(2) Group specification
81
H
to A0
H
: All stations in group No.1 to 32
(Setting is available when the execution type is set to "0: No
arrival confirmation" in (S1)+0.)
(3) All stations
FF
H
: All stations of the target network No. (Except the own
station)
(Setting is available when the execution type is set to "0: With
arrival confirmation" in (S1)+0.)
To specify a group or all stations
• Set "0000
H
" or "03FF
H
" for Target station's CPU type (S1+3).
( Page 329, Section 9.2.2 (3))
• When the target station is on CC-Link IE Field Network, group
specification cannot be performed.
• To check if data has been properly written in the target station,
check the write destination device on the target station.
1 to 120
81
H
to A0
H
FF
H
User
(S1)+6 — Unused 0User
(S1)+7
Number of
resends
1) For instruction execution
Specify the number of times the instruction is to be resent when
it is not completed within the monitoring time specified in
(S1)+8. (Setting is available when the execution type is set to
"1: With arrival confirmation" in (S1)+0.)
0 to 15 User
2) At instruction completion
The number of resends executed (result) is stored. (Setting is
valid when the execution type is set to "1: With arrival
confirmation" in (S1)+0.)
— System
(S1)+8
Arrival monitoring
time
Specify the monitoring time required for instruction completion.
(Setting is available when the execution type is set to "1: With arrival
confirmation" in (S1)+0.)
If an instruction is not completed within this time, it will be resent the
number of times specified in (S1)+7.
0: 10 seconds
1 to 32767: 1 to 32767 seconds
0 to 32767 User
(S1)+9
Write data length
*3
Specify the write data size of (S2) to (S2)+n.
When the target station is QCPU/RCPU/LCPU: 1 to 8192 words
When the target station is QnACPU: 1 to 480 words
When specifying 961 words or more, use channel 9 or 10 for the own
station.
1 to 8192
(1 to 960 when the
own station is a
safety CPU)
User
(S1)+10 — Unused 0User
Device Item Setting data Setting range
Setting
side
*1
Group No.1 81H
Group No.2 82H
Group No.32 A0H