418
(5) Program example
The following is a program in which, when SB0034 turns ON, data sent from station No.1 by the SEND instruction
are read out from channel 5 into D770 to D773.
• SEND instruction: Page 400, Section 9.9
(a) System configuration example
Same as in the program example of the SEND instruction.
(b) Devices used in the program example
• Special relays (SM) and link special relays (SB)
Remark
• For the details of link special relay (SB): Page 568, Appendix 1
• Devices used by the user
Device Description Device Description
SM400 Always ON SB0047 Baton pass status (own station)
SB0034 RECV execution request flag (channel 5) —
Device Description Device Description
M165 Completion device D616 Error code storage device
M166 Completion status indication device
D770 to
D773
Receive data storage device
D370 to
D387
Control data —