625
APPENDICES
A
Appendix 4 Comparison Between CC-Link IE Controller Network and MELSECNET/H
Appendix 4.3 Link special relays (SB) and link special registers (SW)
SB009C
Send transmission path
mismatch status
SB0065 Loopback status
(No. changed)
• The loopback is performed
when the send
transmission path is
inconsistent in the CC-Link
IE Controller Network.
• The cause of loopback
can be checked by Own
station's loop status
(SW0064).
SB00A0
RECV instruction execution
request flag (1)
SB0030
RECV execution request
flag (1)
(No. changed)
None
SB00A1
RECV instruction execution
request flag (2)
SB0031
RECV execution request
flag (2)
SB00A2
RECV instruction execution
request flag (3)
SB0032
RECV execution request
flag (3)
SB00A3
RECV instruction execution
request flag (4)
SB0033
RECV execution request
flag (4)
SB00A4
RECV instruction execution
request flag (5)
SB0034
RECV execution request
flag (5)
SB00A5
RECV instruction execution
request flag (6)
SB0035
RECV execution request
flag (6)
SB00A6
RECV instruction execution
request flag (7)
SB0036
RECV execution request
flag (7)
SB00A7
RECV instruction execution
request flag (8)
SB0037
RECV execution request
flag (8)
SB00A8 Online test instruction — —
(Content
changed)
• Delete the sequence
program for the
corresponding part.
• The result of a test can be
checked by CC IE Control
diagnostics in the CC-Link
IE Controller Network
module.
SB00A9 Online test completion — —
SB00AA
Online test response
instruction
——
SB00AB
Online test response
completion
——
SB00AC Offline test instruction
SB0090 to
SB0099
Page 568, Appendix
1 (4)
(Content
changed)
The completion status of an
offline test can be checked
by SB0090 to SB0099 of the
CC-Link IE Controller
Network module.
SB00AD Offline test completion
SB00AE
Offline test response
instruction
SB00AF
Offline test response
completion
SB00EE Transient error SB008F Transient error
(No. changed)
None
SB01C4
Remote sub-master station
switching acceptance status
——
—
Delete the sequence
program for the
corresponding part.
S
B01C5
Remote sub-master station
switching status
——
SB01C8
Send/receive device number
valid/invalid status
——
SB01E0
Network type consistency
check
——
MELSECNET/H CC-Link IE Controller Network
Compatibility
Precautions for
replacement
No. Name No. Name