11 - 29
11.7 SoftGOT-GOT Link Function Setting
11.7.3 SoftGOT-GOT link function setting operation
3 Operating priority guaranteed time
Relation between the authorization obtained time and the operating priority
guaranteed time
When the followings are set, the authorization obtained time is prioritized. (After the
authorization obtained time is elapsed, the GOT automatically obtains the
authorization.)
1sec or more is set for the authorization obtained time.
The authorization guarantee time is set longer than the authorization obtained
time.
3 If the button is touched before the
button, the left dialog box appears.
4 Touch the button to return to the
[Operation] screen
1 If touch the display area of the operating
priority guaranteed time, a keyboard is
displayed.
Enter the operating priority guaranteed
time with the keyboard.
2 Setting contents are defined if
button is touched.
3 If touch button without touching
button, the dialog mentioned left is
displayed.
4 Touching the button restarts GOT.