EasyManuals Logo

Moons' M2 Series User Manual

Moons' M2 Series
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
M Series AC Servo
User Manual
42
Rev. 1.0
7/31/2019
400-820-9661
X12 X12 30
Speed Selecting Input 3 in change Speed mode.
General purpose input.
COM COM 7 X9-X12 COM point.
High-Speed
Pulse Inputs
PULSH1 44
High-speed pulse inputs (+5VDC line drive input).The max. input frequency is 2MHz.
Three different pulse command can be selected:
Pulse & Direction
CW Pulse and CCW Pulse
A Quadrature B pulse
(NOTE: DO NOT use it with X1/X2 both. )
PULSH2 45
SIGNH1 46
SIGNH2 47
Analog Input
Signal 1
ANA1 16
In velocity command mode in analog velocity mode. The offset, dead band,
function of analog input 1 can be set by M Servo Suit or parameters
P-51, P-55 and P-60.
Sets or requests the analog Input gain that relates to motor position
when the drive is in analog position command mode.
Sets or requests the gain value used in analog velocity mode.
General Analog Input in Q mode.
DGND 15 Digital Ground for Analog input.
Analog Input
Signal 2
ANA2 18
In torque command mode in analog torque mode. The offset, dead band, function of
analog input 2 can be set by M Servo Suit or parameters P-53, P-57 and P-61.
General Analog Input in Q mode
DGND 17 Digital Ground for Analog input.

Table of Contents

Other manuals for Moons' M2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moons' M2 Series and is the answer not in the manual?

Moons' M2 Series Specifications

General IconGeneral
BrandMoons'
ModelM2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals