5 - 156 WiNG 5.5 Access Point System Reference Guide
10. Click the Path Method SNR tab to configure the signal to noise ratio values when selecting the path to the mesh point
root.
Figure 5-99 Mesh Point Auto Channel Selection Path Method SNR screen
Off-channel Duration Configure the duration in the range of 20 - 250 milliseconds for the Off Channel Duration
field. This is the duration the scan dwells on each channel when performing an off
channel scan.
Off-channel Scan
Frequency
Configure the time duration in seconds between two consecutive Off Channel Scans. Set
a duration between 1 - 60 seconds.
Meshpoint Root - Sample
Count
Configure the number of scans to be performed for data collection before a mesh channel
is selected. Set a value between 1 - 10 scans.
Meshpoint Root - Channel
Hold Time
Configure the minimum duration to stay on a selected channel before the channel
conditions are reassessed for a possible channel change. Set a value between 0 - 1440
minutes. Set this value to ‘Zero’ (0) to prevent a automatic channel selection from
happening.