4-47
4.8 Machine malfunction
No. Symptom What to confirm Countermeasure
1
TheLCDshows
nothing.
1.Isthemachineinenergysavemode? Yes
No
Presstheenergysavekey,andrelease
the mode.
Check No.2.
2.Isthepowercablepluggedcorrectly? Yes
No
Check No.3.
Plug the cable correctly.
3.IsthepowerswitchOn? Yes
No
Check No.4.
Poweron.
4. DoestheDCoutputvoltagesfrom
thepowersupplyunittoconnector
P3 on the main control boarhavethe
followingoutput?
Pin 7, 9 +3.3 V
Pin 15, 17 +5.0 V
Pin 2, 4, 6 +12.0V
Pin 12, 14 +24.0V
Pin 1, 3, 5,
8, 10, 11, 13,
19, 21, 23
GND
Yes
No
Check No.5.
Replacethepowersupply.
5. Isthefollowingconnection OK?
•LCD assembly to the Panel PCB. (P8)
•Panel PCB (P1:) to the harness to the
main control board. (P5A)
Yes
No
Check No.6.
Reconnect the connection or replace
the harness.
6. If you replace the panel board, the
symptomwillbexed.
Yes
No
Replace the panel board.
Check No.7.
7. If you replace the main board, the
symptomwillbexed.
Yes
No
Replace the main control board.
Replace the machine.
2
TheLCDshows
“Please close
the flashing
cover.”
1.Ifyouclosetheashingcover,the
symptomwillbexed.
Yes
No
Solved.
Check No.2.
2.Isthecoversecuredrmlyby
screws?
Yes
No
Check No.3.
Securethecoverproperly.
3.Isthemessageshownafterenergy
savemodeisreleased?
Yes
No
Check No.4.
Check No.5.
4.DoestheLPHboardP93-8have
+24V output?
Yes
No
Check No.5.
Check No.6.
5. Press the sensor in the message and
check the output changes to +3V
through GND. (The interlock +24V
through GND.)
No Replace the sensor or the harness.
Interlock : LPH board P93-11 Yes Check No.6.
JAMC1 : LPH board P93-3 Yes Check No.6.
JAMC2: Main control board P17-7 Yes Check No.7.
ADFcover:MaincontrolboardP82-1 Yes Check No.7.
6. If you replace LPH board or the con-
nectingharness,themessagewill
disappear.
Yes
No
Replace the circuit board or the har-
ness.
Check No.7.
7. If you replace the main control board,
thesymptomwillbexed.
Yes
No
Replace the main control board.
Replace the machine.

Table of Contents

Other manuals for Muratec MFX-2550

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Muratec MFX-2550 and is the answer not in the manual?

Muratec MFX-2550 Specifications

General IconGeneral
BrandMuratec
ModelMFX-2550
CategoryAll in One Printer
LanguageEnglish

Related product manuals