Machine Parameter 286 ~ 287— Factory use only
Machine Parameter 288
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Current adjustment
Transparency sheets (OHP)
The plus setting increases
the current and the minus
setting decreases it.
Each setting changes by
0.11 mA.
When transfer problems occur, adjust
this parameter.
Switch 76543210Settings
31 steps 00011111 +3.41 mA
:
8 steps 00001000 +0.88 mA
:
00000000 0 mA Initial setting
-1 steps 10000001 -0.11 mA
-2 steps 10000010 -0.22 mA
:
-8 steps 10001000 -0.88 mA
:
-31 steps 10011111 -3.41 mA
WhenSwitch7is“1”,itmeans“-”.Forexample,
“10000001” means “-0.11 mA”.
NOTE
•Adjustingthemtoomanystepsaffecttheprint
quality.Justtrytodecreaseoneortwosteps
at first.
•DONOTadjustthestepslargerthan31or
smaller than -31.
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Machine Parameter 289
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Current adjustment
LetterandLegalsize
Plain paper back side
The plus setting increases
the current and the minus
setting decreases it.
Each setting changes by
0.11 mA.
When transfer problems occur, adjust this param-ur, adjust this param-r, adjust this param-this param-
eter.
Switch 76543210Settings
31 steps 00011111 +3.41 mA
:
8 steps 00001000 +0.88 mA
:
00000000 0 mA Initial setting
-1 steps 10000001 -0.11 mA
-2 steps 10000010 -0.22 mA
:
-8 steps 10001000 -0.88 mA
:
-31 steps 10011111 -3.41 mA
WhenSwitch7is“1”,itmeans“-”.Forexample,
“10000001” means “-0.11 mA”.
NOTE
•Adjustingthemtoomanystepsaffecttheprint
quality.Justtrytodecreaseoneortwosteps
at first.
•DONOTadjustthestepslargerthan31or
smaller than -31.
6 0
5 0
4 0
3 0
2 0
1 0
0 0