EasyManua.ls Logo

Net research NetProbe 2000 - Page 120

Net research NetProbe 2000
351 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
120
Check the BERT main screen and observe the following:
The real-time PAT SYNC is green. Red
indicates a problem. If these indicators are
red, you should check all circuit connections
and Co-Dir setup.
The history indicators are gray. Red
indicates a problem. If a PAT SYNC event
occurs, the corresponding gray history area
will remain red until it is reset.
Error counters and Pat Loss (pattern loss)
report 0 or at least are not quickly
incrementing. If these are quickly
incrementing, check all circuit connections
and Co-Dir setup.
Tip:
Click on the history indicator box
to reset the history indicator.