"FD 100/320Gbps NT and FX NT IHub System
Basics, Management and OAM Guide"
Security
Issue: 10 3HH-11982-AAAA-TQZZA 61
4.4.2.19 shutdown
Table 55 shutdown command
4.4.2.20 ipv6-filter
Table 56 ipv6-filter command
Description This command configures matching on the SYN bit being set or reset in the control bits of the
TCP header of an IP packet as an CPU filter match criterion.
The SYN bit is normally set when the source of the packet wants to initiate a TCP session with
the specified destination IP address.
The no form of the command removes the criterion from the match entry.
Parameters true Specifies matching on IP packets that have the SYN bit set in the control bits of the
TCP header of an IP packet.
false Specifies matching on IP packets that do not have the SYN bit set in the control bits
of the TCP header of the IP packet.
Item Description
(2 of 2)
Item Description
Syntax [no] shutdown
Context configure>system>security>cpu-filter>ip-filter
Description The shutdown command administratively disables the entity.
The no form of the command puts an entity into the administratively enabled state.
Shutdown/no shutdown will reset counters on all ip-filter entries.
Item Description
Syntax [no] ipv6-filter
Context configure>system>security>cpu-filter
Description This command enables the context to configure IPv6 filter parameters.