7705 SAR Interfaces
212
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
To complete the MC-APS configuration, log on to the protection node, configure an
APS group with the same APS ID as the working group, and configure the protection
circuit. The MC-APS signaling path is established automatically when APS groups
with matching IDs are both configured.
The following CLI syntax shows an example of configuring an MC-APS protection
circuit on a node.
Example: config# port aps-2
config>port# aps
config>port>aps# protect-circuit 1/3/2
Use the config port info command to display port configuration information.
*A:7705:Dut-D# configure port aps-2
*A:7705:Dut-D>config>port# info
----------------------------------------------
aps
neighbor 10.10.10.2
protect-circuit 1/3/2
exit
sonet-sdh
path sts1-1
payload vt15
no shutdown
exit
path vt15-1.1.1
no shutdown
exit
exit
tdm
ds1 1.1.1
channel-group 1
encap-type cem
timeslots 1-24
no shutdown
exit
no shutdown
exit
exit
no shutdown
----------------------------------------------
SC-APS and MC-APS on the 2-port OC3/STM1 Channelized Adapter card (access
side) normally support only TDM CES (Cpipes). SC-APS and MC-APS support
Epipes with TDM SAPs when the MEF 8 service is used. The following CLI syntax
shows an example of TDM CESoETH with MEF 8 for APS.
*A:7705:Dut-D# configure service epipe 1
*A:7705:Dut-D>config>epipe# info
----------------------------------------------
epipe 1 customer 1 vpn 1 create
description "Default epipe description for service id 1"
endpoint "X" create