7705 SAR Interfaces
336
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
Parameters alarm-output — identifies the output relay, in the following format:
relay-slot/mda.d-relay-num [name]
where:
slot = slot number of the card in the chassis (always 1 on the 7705 SAR)
mda = Auxiliary Alarm card slot number
d = digital output
relay-num = output relay number (1to 8)
name = name assigned to the output relay
for example:
relay-1/3.d-5
doorHolder5
The name option lets users assign a more meaningful name (must be unique) to the
output relay; for example, doorHolder5 might be more meaningful to a user than the
output relay identifier relay-1/3.d-5. Once the name has been configured, it can be
used interchangeably with the alarm identifier; for example, doorHolder5 can be used
instead of relay-1/3.d-5 when performing a show>external-alarms>output
command.
name
Syntax name name-string
no name
Context config>external-alarms>input
config>external-alarms>output
Description This command configures a name for the alarm input or output relay. The configured name
must be unique within the external alarms context; therefore, it must not be the same as an
alarm-input name configured for the trigger or input command, or an alarm-output name
configured for the output command. For example, alarm-1/3.d-1 or doorOpen1 cannot be
used as a name for any alarm input, and relay-1/3.d-5 or doorHolder5 cannot be used as a
name for any output relay.
The no form of this command does not associate a name with the alarm input or output relay.
Default no name
Parameters name-string — specifies a unique name for the alarm input or output relay (maximum of
15 characters)