Training Guide Course No. 196514
Level 2 Maintenance, X-1000 Series Dispensing Systems 2-145 P/N 196515 (Revision A)
Lesson 2-16
Stop Pins/Lift Tables/Clamp Bars
A. Introduction
When a part is conveyed into the system, a sensor detects its presence and
indexes the part. Stop pins are raised to stop the board transport. Clamp bars
or lift tables raise to hold the part in place. It may be necessary to adjust the
tooling flow controls that regulate the air pressure provided to the lift tables and
clamp bars.
B. Enabling Objective
2.16 Identify the steps required to adjust the tooling flow controls.
C. Topic Outline
1. Introduction
2. Overview
 Stop Pins
 Lift Tables/Clamp Bars
 Airflow Adjustment
3. Summary and Review