Level 2 Maintenance, X-1000 Series Dispensing Systems 1-18 P/N 196515 (Revision A)
+24V
RTE44024S
RTE44024S
6
4
2
5
3
1
6
4
2
K2
K3
A1
A2
5L3 3L2
6T3 4T2
A1
A2
5L3 3L2
6T3 4T2
+24V_START_B
+24V_START_A
+24V_STOP_A
+24V_STOP_B
SELF-LATCHING
RELAYS
(
AC FROM
WALL)
RETURN
RETURN
RETURN
RETURN
AC RELAYS
5
3
1
ON BUTTON
OFF BUTTON
0
I
VENT AIR
SWITCHES
REAR EMO
FRONT EMO
LATCHING, DP, NC (x2)
MOMENTARY, DP, NC
SPST-NC (x2)
MOMENTARY, DP, NO
EMO
CIRCUIT,
X-1000
(
A
C TO MACHINE
)
Diagram Sheet 1-4-2
EMO Circuit Diagram

Table of Contents