Service Manual
683311W
4-17
STATUS REQUEST NO WAIT -
WAIT
(Only if the vertical magnetic option is present)
OPTION VERTICAL MSRW
DENSITY 80 BPI - 160 BPI
RETRY 3 - 1
PNS SELECTION N - Y
(if) PNS SELECTION: Y
PNS # 3290 N - Y
PNS # 3860 N - Y
SAVE PARAMETERS Y - N
This parameter determines the timing of the status
reply upon reception of an ESC j command. By
selecting NO WAIT, the reply will be provided as soon
as possible and simultaneously with the execution of
print or paper movement commands. By selecting
WAIT, the status reply will be provided at the end of
the print job.
Informs when the option is installed
Sets data density.
Indicates the number of read retries before the error
condition is signalled.
Selecting (Y) gives access to the PNS selection menu
in the Olivetti 2845 environment.
Enables the conversion of all the characters of the
ASCII table to those of column 3X (numeric column).
Reduces the number of trailing "0" on the vertical
magnetic stripe recording.
Defines whether to store (Y) or not (N) the settings
made in this Setup section.
Note: If the right vertical magnetic unit option is present, SIDE = R must be selected so that the
option can be correctly handled.