683311W
4-24
4.5.2 CONFIGURATION PARAMETERS
4.5.2.1 CONFIGURATION INTERFACE PARAMETERS
Data transmission/reception rate.
Data format: 7 or 8 bits.
Presence/type of parity control: none, odd, even.
Number of stop bits.
Handshaking selection.
"Data Set Ready" management selection.
"Data Carrier Detector" management selection.
Saves (Y) or not (N) the selected arrangement in this
set-up section.
INTERFACE: RS 232
BAUD RATE: 9600 - 4800
2400 - 1200
BIT/CHAR: 7 - 8
PARITY: NONE - ODD -
EVEN
STOP BIT: 1 - 2
HANDSHAKING: DTR MODE -
XON MODE
DSR: ENABLE- DISABLE
DCD: ENABLE- DISABLE
SAVE PARAMETERS:Y - N