EasyManua.ls Logo

Olivetti PR2 - Configuration Parameters

Olivetti PR2
179 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
683311W
4-24
4.5.2 CONFIGURATION PARAMETERS
4.5.2.1 CONFIGURATION INTERFACE PARAMETERS
Data transmission/reception rate.
Data format: 7 or 8 bits.
Presence/type of parity control: none, odd, even.
Number of stop bits.
Handshaking selection.
"Data Set Ready" management selection.
"Data Carrier Detector" management selection.
Saves (Y) or not (N) the selected arrangement in this
set-up section.
INTERFACE: RS 232
BAUD RATE: 9600 - 4800
2400 - 1200
BIT/CHAR: 7 - 8
PARITY: NONE - ODD -
EVEN
STOP BIT: 1 - 2
HANDSHAKING: DTR MODE -
XON MODE
DSR: ENABLE- DISABLE
DCD: ENABLE- DISABLE
SAVE PARAMETERS:Y - N