Menu Tables
FQ-CR2 User’s Manual
159
Appendices
10
Inspect Tab Page
Menu command Description Setting range Data Refer-
ence
Inspection
Item selected
Add item Used to add, modify, delete, copy, or
change the name of an inspection item.
2D code --- p. 47
Modify --- --- p. 48
Delete --- p. 48
Copy ---
Rename 15 alphanumeric characters ---
Settings
Teach
Insp. region Changes the inspection region. --- Scene
Details
Code type Selects the type of code that is scanned. DataMatrix, QR Code, Auto (default) Scene
Auto length Sets whether the code length is automat-
ically acquired.
OFF, ON (default) Scene
Reverse Sets Normal/Reverse. Normal, Reverse, Auto (default) Scene
Code color Sets the code color. Black, White, Auto (default) Scene
Fast mode Specifies whether fast mode is set.
When fast mode is set, the scanning time
is shorter.
OFF (default), ON Scene
Shape (Data Matrix) Sets the code shape. Square, Rectangle, Auto (default) Scene
QR Code Model
(QR Code)
Sets the QR code model. Model 1, Model 2, Auto (default) Scene
Error Correction
Level (QR Code)
Sets the error correction level (ECC
level).
L (7%), M (15%), Q (25%), H (30%),
Auto (default)
Scene
Cell Sets the number of cells of the code. QR Code
21 × 21, 25 × 25, 29 × 29, 33 × 33,
37 × 37, 41 × 41, 45 × 45, 49 × 49,
53 × 53, 57 × 57, Auto
DataMatrix (Square)
10 × 10, 12 × 12, 14 × 14, 16 × 16,
18 × 18, 20 × 20, 22 × 22, 24 × 24,
26 × 26, 32 × 32, 36 × 36, 40 × 40,
44 × 44, 48 × 48, 52 × 52, 64 × 64, Auto
DataMatrix (Rectangle)
8 × 18, 8 × 32, 12 × 26, 12 × 36,
16 × 36, 16 × 48, Auto
Scene
Retry details
Max Count
(Normal retry)
Sets the number of retries.
0 to 8, Default: 4 Scene
Interval
(Normal retry)
Sets the retry interval (msec).
0 to 8, Default: 100 Scene
Brightness step
(Exposure retry)
Sets the exposure time step (msec). Brightness step:
1 to 20, Default 2
shutter speed step:
0.01 to 1.00 (Default: 1.00)
Scene
Increment count
(Exposure retry)
Sets the increment count for the bright-
ness (shutter speed) step.
0 to 10, 2 (default) Scene
Decrement count
(Exposure retry)
Sets the decrement count for the bright-
ness (shutter speed) step.
0 to 10, 2 (default) Scene
FQ Sensor User Manual.book 159 ページ 2011年7月8日 金曜日 午後2時30分