Menu Tables
160
FQ-CR2 User’s Manual
In/Out Tab Page
Menu command Description Setting range Data Refer-
ence
Log setting
Statistical data Sets whether to record the number of
measurements and the number of NG
overall judgements.
ON (default) or OFF System p. 80
Image logging Sets the parameter to log measurement
image data.
All, Only NG, or None (default) System p. 76
p. 80
Data logging Sets the parameter to log measurement
data from inspection items.
All (default), Only NG, or None (default) System
Delete Log Resets the log data without turning OFF
the power supply.
--- --- p. 80
I/O setting
I/O terminals
Output
OUT0 Used to assign output signals to OUT0,
OUT1, and OUT2.
OR (Total judgement) (default) or OR0
(Item0 judgement) to OR31 (Item31
judgement)
System p. 102
OUT1 BUSY (default) or OR0 (Item0 judge-
ment) to OR31 (Item31 judgement)
System
OUT2 ERROR (default) or OR0 (Item0 judge-
ment) to OR31 (Item31 judgement)
System
Output polarity Sets the ON condition for the OR signal. OK: ON or NG: ON (default) System p. 106
Output mode Sets the output timing for the judgement
result.
One-shot output or Level output (default) System p. 104
Output delay When one-shot output mode is selected,
this parameter sets the delay from when
measurement processing is completed
until when the OR signal turns ON.
0 to 1,000 ms (default: 0 ms) System
Output time When one-shot output mode is selected,
this parameter sets the time that the OR
signal is ON.
0 to 1,000 ms (default: 5 ms) System
BUSY output Specifies when to turn OFF the BUSY
signal after starting measurement pro-
cessing.
Measurement (default), Data logging,
Image logging, or Result display
System p. 78
BUSY polarity Sets the ON condition for the BUSY sig-
nal output.
BUSY: ON (default), READY: ON System p. 106
Output trigger
error
Sets whether an error is output if a trig-
ger is received while BUSY.
ON (default), OFF System p. 107
Input
Input mode Specifies whether to use functions other
than scene switching for external parallel
commands.
Standard mode (default) or Expanded
mode
System p. 107
FQ Sensor User Manual.book 160 ページ 2011年7月8日 金曜日 午後2時30分