Menu Tables
FQ-CR2 User’s Manual
161
Appendices
10
I/O setting
Ethernet
Output data set --- Data 0 to data 31
Scene
p. 120
[MENU]
Settings Sets data to output to selected data
number.
Text strings of the set inspection items.
Scene
Rename Changes the name of the selected data
number.
The name can be changed to a name
with up to 15 alphanumeric characters.
---
Copy Copies the contents registered in the
selected data number to another data
number.
--- ---
Delete Clears the content of the selected data
number.
--- ---
Output character set --- Inspection Items 0 to 31 Scene
String output on/
off
Selects whether the scanned string is
output by Ethernet.
ON, OFF (default) Scene
Partial output on/
off
Selects whether an output range is spec-
ified.
ON, OFF (default) Scene
Output string
setup
Sets the starting and ending digits of out-
put.
1 to 1024 Scene
NG String out-
put on/off
Selects whether an NG scan result is
output by Ethernet.
ON, OFF (default) Scene
Output form --- --- ---
Output form Selects the format of the data to be
output.
ASCII (default) or Binary
Scene
p. 122
When
output
format
is
ASCII
Digits
of inte-
ger
Sets the digits of the integer part,
including the sign. However, + is not out-
put for positive numbers.
Example: Setting 4-digit data: −5963 is
output as −999.
1 to 10 (Default: 6)
Scene
Digits
of deci-
mal
Sets the output digits for the decimal
part. If it is set to 0, the decimal part is
rounded off before the data is output.
0 to 4 (default: 4)
Scene
Minus Selects what to display as the sign when
the number is negative.
− (Default) or 8
Scene
0 sup-
press
Selects the method to adjust unused dig-
its on the left in output data.
ON: Zeros are inserted for unused digits.
OFF: Spaces are inserted for unused
digits.
Example:
The following examples are for when five
integer digits and three decimal digits are
set and the data is 100.000.
ON: 00100.000
OFF: _100.000 (The underscore indi-
cates a space.)
ON or OFF (default)
Scene
Output form
When
Output
Format
Is
ASCII
Field
separa-
tor
Selects the separator to use between
output data.
None (default), comma, tab, space, CR,
LF, or CR+LF
Scene
p. 130
Record
separa-
tor
Selects the separator to use between
sets of output data.
None (default), comma, tab, space, CR,
LF, or CR+LF
Scene
p. 122
When
output
format
is
Binary
Deci-
mal
output
form
Selects the numerical expression for
binary output.
Fixed-decimal-point data is multiplies by
1,000 and the result is output.
Floating-point decimal or fixed decimal
(default)
Scene
p. 123
I/O monitor
I/O monitor Used to check I/O connections. --- --- p. 75
Menu command Description Setting range Data Refer-
ence
FQ Sensor User Manual.book 161 ページ 2011年7月8日 金曜日 午後2時30分