Setting the Retry Function
92
FQ-CR2 User’s Manual
Setting normal retry
Set the retry mode to [Normal retry] in "Retry details".
(Setup Mode) [Sensor settings] [Retry details]
Specify the maximum count and interval.
[Inspect] [Retry details]
Setting exposure retry
Set the retry mode to [Exposure retry] in "Retry details".
(Setup Mode) [Sensor settings] [Retry details]
Set the brightness (shutter speed) step, increment count, and decrement count.
[Inspect] [Retry details]
1 Press [Normal retry] for the retry mode.
2
Press OK.
1 Set the maximum count and interval.
Parameter Settings Description
Max count 0 to 20, (default: 4) Sets the maximum number of retries.
Interval 32 to 999, (default: 100) Sets the capture interval (msec).
1 Press [Exposure retry] for the retry mode.
1 Set the shutter speed step, increment count, and
decrement count.