3-4
Synchronizing Project Data and Sen-
sor Setting Data
3-4-1
Transferring Project Data to the Sensor
Project data and setting data for the FH/FHV vision sensor can be synchronized together.
1 Establish an online connection for the vision sensor.
Establish an online connection for the FH/FHV vision sensor that you wish to synchronize to
the project data.
For details, refer to 3-3 Establishing an Online Connection with a V
ision Sensor on page 3 - 4.
2 Select the data that you wish to have transferred.
The Data transfer window will appear once you are online.
Precautions for Correct Use
• An image being managed by the Registered Image Manager Tool will not be transferred.
•
When you check the Scene Group Saving Destination Settings and transfer processing is
executed as Transfer to Sensor, the scene group saving destination data saved in the
project will be transferred. If the saving destination specified in the transferred Scene group
saving destination data does not exist, the saving destination setting will be cleared.
3 Connecting with a Vision Sensor
3 - 7
FH/FHV Series Vision System Operation Manual for Sysmac Studio (Z343-E1)
3-4 Synchronizing Project Data and Sensor Setting Data
3