Enable and Verify Newly Installed DIMMs
a.
Set the virtual keyswitch to diag so that POST will run in Service mode.
-> set /HOST keyswitch_state=Diag
Set 'keyswitch_state' to 'Diag'
b.
Power cycle the server.
-> stop /System
Are you sure you want to stop /System (y/n)? y
Stopping /System
-> start /System
Are you sure you want to start /System (y/n)? y
Starting /System
c.
Check if the host has been powered off.
Allow approximately one minute before performing this step. Type the show /HOST
command. When the host is powered off, the console displays status=Powered Off.
d.
Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output indicates that
POST did not detect any faults:
-> start /SYS/console
...
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
Note - The server might boot automatically at this point. If so, go directly to Step 4f. If the
server remains at the OpenBoot prompt (ok) go to Step 4e.
e.
If the server remains at the OpenBoot prompt, type boot.
f.
Return the virtual keyswitch to Normal mode.
-> set /HOST keyswitch_state=Normal
Set 'keyswitch_state' to 'Normal'
110 SPARC T5-2 Server Service Manual • February 2017

Table of Contents

Other manuals for Oracle SPARC T5-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC T5-2 and is the answer not in the manual?

Oracle SPARC T5-2 Specifications

General IconGeneral
BrandOracle
ModelSPARC T5-2
CategoryServer
LanguageEnglish

Related product manuals