Application Macros 5-27
690+ Series Frequency Inverter
Compensation
COMPENSATIONS [817] 0.00 %
INERTIA COMP [818] 0.00 %
SCALED RATE [819] 0.00 %
LINE SPEED RATE [820] 0.00 %
10.00 % [805] DIAMETER
10.00 % [806] MINIMUM DIAMETER
0.00 % [807] VARIABLE INERTIA
0.00 % [808] FIXED INERTIA
0.00 % [809] WIDTH
FALSE [810] UNWIND
0.00 % [811] LINE SPD DEMAND
0.00 % [812] RATE CAL
FALSE [813] REVERSE
0.00 % [814] DYNAMIC COMP
0.00 % [815] STATIC COMP
0.00 % [816] MOD REEL SPEED
Diameter Calc
CURRENT CORE [834] 10.00 %
DIAMETER [835] 10.00 %
MOD LINE SPEED [836] 0.00 %
MOD WINDER SPEED [837] 0.00 %
FALSE [821] DIAMETER HOLD
FALSE [822] PRESET ENABLE
FALSE [823] SELECT CORE 2
FALSE [824] SEL EXT DIAMETER
FALSE [825] TENSION ENABLE
10.00 % [826] CORE 1
10.00 % [827] CORE 2
5.00 s [828] DIAMETER TC
0.00 % [829] EXT DIAMETER
0.00 % [830] LINE SPEED
10.00 % [831] MINIMUM DIAMETER
5.00 % [832] MINIMUM SPEED
0.00 % [833] REEL SPEED
Taper Calc
TAPERED DEMAND [850] 0.00 %
TENSION DEMAND [851] 0.00 %
FALSE [838] HYPERBOLIC TAPER
FALSE [839] STALL ENABLE
FALSE [840] BOOST ENABLE
FALSE [841] FIXED BOOST
FALSE [842] FIXED STALL TEN
0.00 % [843] CURRENT CORE
10.00 % [844] DIAMETER
0.00 % [845] BOOST
1.000 s [846] TENSION RAMP
0.00 % [847] STALL TENSION
0.00 % [848] TAPER SPT
0.00 % [849] TENSION SPT
Speed Calc
SPEED DEMAND [784] 0.00 %
UP TO SPD (UTS) [785] TRUE
FALSE [774] UNWIND
FALSE [775] OVER-WIND
FALSE [776] OVER SPD ENABLE
5.00 % [777] UTS THRESHOLD
0.00 % [778] LINE SPEED
0.00 % [779] MOD REEL SPEED
10.00 % [780] DIAMETER
10.00 % [781] MINIMUM DIAMETER
0.00 % [782] OVER SPEED
0.00 % [783] SPEED TRIM
Winde
r
Encoder Functions
Phase Move
ACTIVE [1509]
FALSE
DISTANCE LEFT [1508]
0.00
FALSE
[1504] ENABLE
1.0
[1505] DISTANCE
0.0000
[1506] DISTANCE FINE
1.0
[1507] RATE
Phase Offset
ACTIVE [1512]
FALSE
0.0
[1510] OFFSET
0.0000
[1511] OFFSET FINE
Torque Calc
POS TORQUE LIMIT [790] 150.00 %
NEG TORQUE LIMIT [791]
-150.00 %
TRUE [786] OVER-WIND
TRUE [1550] REWIND
FALSE [787] TENSION ENABLE
0.00 % [788] TORQUE DEMAND
150.00 % [789] TORQUE LIMIT
Encoder Speed 1
SPEED HZ [1538]
0.0 Hz
SPEED [1539]
0.0 %
MASTER
ENCODER
[1532] SOURCE
2048
[1533] LINES
FALSE
[1534] INVERT
1500 rpm
[1535] MAX SPEED
0.50 s
[1537] FILTER TIME
Encoder Speed 2
SPEED HZ [1546]
0.0 Hz
SPEED [1547]
0.0 %
MASTER
ENCODER
[1540] SOURCE
2048
[1541] LINES
FALSE
[1542] INVERT
1500 rpm [1543] MAX SPEED
0.50 s
[1545] FILTER TIME
Phase Auto Gear
SLAVE LENGTH [1599]
0.0000
MASTER LENGTH [1598]
0.0000
GEAR CORRECTION [1597]
0.0000
EXT MARK SLAVE [1596]
FALSE
EXT MARK MASTER [1595]
FALSE
FALSE M MARKS [1594]
0
FALSE S MARKS [1593]
0
MISSED M MARKS [1592]
0
MISSED S MARKS [1591]
0
MASTER MARKS [1590]
0
SLAVE MARKS [1589]
0
READY [1602]
FALSE
SLAVE MARK POS [1832]
0
MASTER MARK POS [1833]
0
TRUE
[1579] RESET
FALSE
[1580] ENABLE
FALSE
[1581] HOLD
1.0000
[1582] NOM MASTER LEN
1.0000
[1583] NOM SLAVE LENGTH
0.1000
[1584] TOLERANCE
20
[1585] INITIAL REPEATS
0.100
[1586] INITIAL FILTER
1.000
[1587] FILTER
FALSE
[1588] RESET COUNTERS
Phase Configure
MASTER POSITION [1529]
0
SLAVE POSITION [1530]
0
FAULT [1531]
FALSE
SLAVE ENCODER
[1524] SLAVE CNT SOURCE
TB ENCODER
[1525] SPD LOOP SPD FBK
8192
[1526] COUNTS PER UNIT
32768
[1836] HIPER COUNT/REV
FALSE
[1835] 1ms CYCLE RATE
1500 upm
[1560] MAX SPEED
2048
[1527] MASTER SCALE A
2048
[1528] MASTER SCALE B
FALSE
[1834] SLAVE INVERT
FALSE [1837] MASTER INVERT
PULSE
[1561] MASTER MARK TYPE
PULSE
[1562] SLAVE MARK TYPE
Phase Control
OUTPUT [1488]
0.00
SPEED OUTPUT [1489]
0.00
POS FEED FWD [1490]
0.00
SLAVE POS (INT) [1841] 0
MASTER POS (INT) [1491]
0
MASTER POSITION [1492]
0.00
MSTR POS+OFFSET [1842]
0
SLAVE POSITION [1493]
0.00
POS ERROR INT [1494]
0
POSITION ERROR [1495]
0.00
FALSE
[1479] RESET (TOTAL)
FALSE [1480] POSITION ENABLE
0.00
[1481] SPEED INPUT
FALSE
[1482] INVERT SPEED OP
0
[1483] GEARING A
0
[1484] GEARING B
0
[1485] FDFWD SCALE
0.00
[1486] OUTPUT SCALE
FALSE
[1487] INVERT OUTPUT
Phase Inch
ACTIVE [1503]
FALSE
FALSE
[1500] ADVANCE
FALSE
[1501] RETARD
0.1000
[1502] RATE
1.000
[1699] RATE SCALE
Phase PID
OUTPUT [1522]
0.00 %
PID OUTPUT [1549]
0.00 %
LIMITING [1523]
FALSE
ERROR [1679]
0.00%
FEED FWD [1680]
0.00%
FALSE [1520] ENABLE
0.00 % [1513] ERROR unused
0.00%
[1514] FEED FWD unused
1.00
[1515] FEED FWD GAIN
0.10
[1516] P GAIN
FALSE
[1843] INT DEFEAT
1.00
[1517] I GAIN
0.00
[1518] D GAIN
0.05 s
[1521] D FILTER TC
300.00%
[1519] LIMIT
Phase Tuning
ACTIVE [1478] FALSE
10.00 s
[1473] PERIOD
FALSE
[1844] SINE WAVE
FALSE
[1474] ENABLE SPEED
1.00 %
[1475] SPEED OFFSET
FALSE
[1476] ENABLE PHASE
1.00
[1477] PHASE OFFSET
Phase Register
CORRECTIONS [1570]
0
STATUS [1571]
0
INCH OFFSET [1565]
0.0000
ERROR COUNTS [1572]
0
ERROR 1573]
0.0000
TRUE
1563] RESET
FALSE
[1564] ENABLE
0.0000
[1566] MARK OFFSET
1.0000
[1567] SLAVE NOM LENGTH
10.00
[1568] VELOCITY
10.00
[1569] ACCELERATION
100.00
[1631] CORRECTION GAIN