EasyManua.ls Logo

Parker ac890 - Page 227

Parker ac890
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The Keypad
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page 8-29
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
POWER BOARD (6511 keypad)
s
E
PROG
HOLD
M
E
Hold down the keys opposite:
-
Power-up the drive, continue
to hold for at least 2 seconds
The power data is stored
M
Number flashes
For example
CODE flashes
E
Now accepted
x
2
E
The diagram above shows a 3-button reset when there is power data stored in the drive. If the drive has no
power data stored, then the “Power Data Corrupt” and “Language Defaults Loaded” alert messages will be
displayed. Press the "E" key to remove the alert messages.
CD/SD 230Vac Units:
Size Model No.
Block 3
Rating Code
Frame B 0003B 0.75 HP/0.55kW 131
0005B 1.5 HP/1.1kW 132
0007B 2 HP/1.5kW 117
0011B 3 HP/2.2kW 118
0016B 5 HP/4.0kW 119
Frame C 0024C 7.5 HP/5.5kW 120
0030C 10 HP/7.5kW 121
CD/SD 400-500 Vac Units:
Size Model No.
Block 3
Rating Code
Frame B 0002B 0.75 HP/0.55kW 133
0003B 1.5 HP/1.1kW 134
0004B 2 HP/1.5kW 135
0006B 3 HP/2.2kW 122
0010B 5 HP/4.0kW 123
0012B 7.5 HP/5.5kW 136
0016B 10 HP/7.5kW 124
S016B
30% more peak
10HP/7.5kW 125
Frame C 0024C 15 HP/11kW 126
0030C 20 HP/15kW 127
S030C
30% more peak
20 HP/15kW 128
Frame D 0039D 25 HP/18.5kW 137
0045D 30 HP/22kW 129
0059D 40 HP/30kW 130