Programming
Page
D-190
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF Name Block Type Range Default ro\rw Notes
6.01 VALUE ANALOG OUTPUT 1 REAL -300.00 to 300.00 % 0.00 % rw
6.05 TYPE ANALOG OUTPUT 1 ENUM 0 : -10..+10 V
1 : 0..+10 V
0..+10 V rw
7.01 VALUE ANALOG OUTPUT 2 REAL -300.00 to 300.00 % 0.00 % rw
7.05 TYPE ANALOG OUTPUT 2 ENUM 0 : -10..+10 V
1 : 0..+10 V
0..+10 V rw
8.02 VALUE DIGITAL INPUT 1 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
9.02 VALUE DIGITAL INPUT 2 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
10.02 VALUE DIGITAL INPUT 3 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
11.02 VALUE DIGITAL INPUT 4 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
12.02 VALUE DIGITAL INPUT 5 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
13.02 VALUE DIGITAL INPUT 6 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
14.02 VALUE DIGITAL INPUT 7 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
15.02 VALUE DIGITAL INPUT 8 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
16.02 VALUE DIGITAL INPUT 9 BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
17.01 VALUE DIGITAL OUTPUT 1 BOOL 0 : FALSE
1 : TRUE
FALSE rw
18.01 VALUE DIGITAL OUTPUT 2 BOOL 0 : FALSE
1 : TRUE
FALSE rw
19.01 VALUE DIGITAL OUTPUT 3 BOOL 0 : FALSE
1 : TRUE
FALSE rw