PREF Name Block Type Range Default ro\rw Notes
108.01 ADVANCE PHASE INCH BOOL 0 : FALSE
1 : TRUE
FALSE rw
108.02 RETARD PHASE INCH BOOL 0 : FALSE
1 : TRUE
FALSE rw
108.03 RATE PHASE INCH REAL 0.0001 to 30.0000 0.1000 rw
108.04 ACTIVE PHASE INCH BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
108.08 RATE SCALE PHASE INCH REAL 0.001 to 30.000 1.000 rw
108.09 RESET PHASE INCH BOOL 0 : FALSE
1 : TRUE
FALSE rw
108.10 OFFSET PHASE INCH REAL _.xxxx 0.0000 ro Output
109.01 ENABLE PHASE MOVE BOOL 0 : FALSE
1 : TRUE
FALSE rw
109.02 DISTANCE PHASE MOVE REAL -3000.0 to 3000.0 1.0 rw
109.03 DISTANCE FINE PHASE MOVE REAL -1.0000 to 1.0000 0.0000 rw
109.04 VELOCITY PHASE MOVE REAL 0.10 to 300.00 % 1.00 % rw
109.05 ACTIVE PHASE MOVE BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
109.06 DISTANCE LEFT PHASE MOVE REAL _.xx 0.00 ro Output
109.07 ACCELERATION PHASE MOVE REAL 0.01 to 3000.00 % 1.00 % rw
109.08 HOLD PHASE MOVE BOOL 0 : FALSE
1 : TRUE
FALSE rw
109.10 OFFSET PHASE MOVE REAL _.xxxx 0.0000 ro Output
109.11 RESET PHASE MOVE BOOL 0 : FALSE
1 : TRUE
FALSE rw
110.01 OFFSET PHASE OFFSET REAL -3000.0 to 3000.0 0.0 rw