12 Appendix
Page 112 Installation manual for PMCtendo DD5/PMCprimo Drive3
12 Appendix
12.1 Transport, storage, maintenance, disposal
Transport: only by qualified personnel
only in the manufacturer’s original recyclable packaging
avoid shocks
temperature -25 to +70°C, max. rate of change 20°C / hour
humidity max. 95% relative humidity, no condensation
The servo amplifiers contain electrostatically sensitive components,
that can be damaged by incorrect handling. Discharge yourself
before touching the servo amplifier. Avoid contact with highly
insulating materials, such as artificial fabrics and plastic films.
Place the servo amplifier on a conductive surface.
if the packaging is damaged, check the unit for visible damage.
In such an event, inform the shipper and the manufacturer.
Packaging: recyclable cardboard with inserts
dimensions : (HxWxD) 115x365x275mm
labeling instrument label on outside of box
Storage: only in the manufacturer’s original recyclable packaging
the servo amplifiers contain electrostatically sensitive components
which can be damaged by incorrect handling. Discharge yourself
before touching the servo amplifier. Avoid contact with highly
insulating materials (artificial fabrics, plastic films etc.).
Place the servo amplifier on a conductive surface.
max. stacking height 8 cartons
storage temperature -25 to +55°C, max. rate of change 20°C / hour
humidity 5 ... 95% relative humidity, no condensation
storage duration < 1 year without restriction
> 1 year: capacitors must be re-formed before
setting up and operating the servo amplifier.
To do this, remove all electrical connections
and apply single-phase 230V AC for about
30 minutes to the terminals L1 / L2.
Maintenance: the instruments do not require any maintenance
opening the instruments invalidates the warranty
Cleaning: if the casing is dirty: clean with isopropanol or similar
do not immerse or spray
if there is dirt inside the unit: must be cleaned by the manufacturer
dirty protective grill on fan: clean with a dry brush
Disposal : you can dismantle the servo amplifier into its principal components
by unscrewing it (aluminum heat sink, steel housing sections,
electronics boards)
disposal should be carried out by a certified disposal company.
We can give you suitable addresses on request.