HUNTER-PRO 32 Intruder Alarm System - Installation Manual
14
4
(+) – Power Supply for Detectors
Power supply for detectors that require DC operating voltage, such as infrared
detectors, beam-detectors etc.
5
KEY – Key
or remote Arming Input
Use momentary or ON/OFF key to arm/disarm the system.
6
S1, S2 – Siren 1 and Siren 2 Outputs
Two siren outputs connected to the same on-board sound generator (driver).
Connect the second siren connection is to a ground (-) connection. Each siren
has a dedicated automatic thermal fuse F2 and F3 (see section 3.6)
7
RELAY – Internal Relay Connections
Three connections to a relay mounted on the PCB. Can be used to activate
various auxiliary accessories such as external lighting, CCTV, external
communicator, electric locks, etc .
The three outputs are C (common), NO (normally open) and NC (normally
closed).
8
SMOKE – Switched Ground
Switched GND for smoke detectors that require reset. Any zone can be
programmed to be a “smoke detector” input; its activation will cause the GND
to disconnect for approximately one minute.
Manual reset is done by pressing and holding the
key.
9
KEYPAD – Connection to keypads
There are four Keypad terminals: Voltage power supply (–) and (+) .OUT is for
data from the control panel to the keypad, and IN is for data from the keypad
to the control panel. An automatic thermal fuse F4 protects the 13.8 VDC
power supply. Up to 8 RXN 400/410 keypads can be connected simultaneously.
ALRM and ON/OFF – Auxiliary Outputs
These terminals have two conditions: disconnect or short to ground. These
outputs serve as indicators to auxiliary units as to system status and alarm
status (see section 5.8).