code for arming/disarming the system. In this case, the keypad will display the
entire system’s status.
A detector that is allocated to several partitions can be installed in order to
protect the entrance of the offices’ hallway (i.e. a zone shared by several/all
partitions). Allocating the entrance zone to all partitions will protect the
entrance, providing all partitions are armed. This zone will be inactive with the
first user that disarms his partition.
2.2.2 Example B
Keypad 2
Partition 1
Partition 3
Partition 2
Partition 8
Keypad 1 Keypad 8Keypad 3
User 1 User 8User 3User 2
Drawing 2-Using partitions (example B)
In example B:
Each partition has it own individual user code and keypad (e.g. user 1 can
activate partition1 but not partition 2).
A user can only arm/disarm his partition only by using his allocated keypad (e.g
user 1 can only arm/disarm his partition using keypad 1).
Each keypad presents only its allocated partition’s status (meaning, keypad 1
displays only partition 1 status, keypad 2 displays only partition 2 status, and
so on).
NOTE:
The keypad displays only its allocated partition’s status, including
arming/disarming the partition, opened zones allocated to this partition, and
zones that triggered the alarm.