Connecting Battery
The HUNTER-PRO 32 incorporates a rechargeable 12V backup battery. The
charging voltage for the battery is 13.8 V.
The system performs two battery tests as well as a manual test:
“Low level” test”: A continuous monitoring for battery failures such
as a disconnected wire, poor contact, etc.
“Under load” test”: Checks the battery capacity. This test is
conducted in the following cases:
Each time the system is armed.
Every day at 24:00.
Upon applying power to the system.
NOTE:
If the "under load" test fails, the system will respond as programmed in the
failure responses (sounding sirens, dialing the Monitoring Station, etc.).
Manual battery test: Enter the Master Code then press and hold the
key for a complete system check that also includes a battery
check.