HUNTER-PRO 32 Intruder Alarm System - Installation Manual
35
Make sure that in “General Parameters” screen (section 5.6.1) the siren is
configured as DC (mark a “+“ under the “D” letter parameter).
Also make sure that JP5 shorts legs 1 and 2 (see drawing 7).
SIREN KEYBOA
Siren with
oscilliator
CONTROL
F3F2
JP5
1
2
3
Drawing 10 Connecting DC Siren
3.6.3 High-Current Stand-Alone Siren
DC Siren with a high-current oscillator (consumes 3 Amp).
The siren is connected between terminal block outputs (S1, S2) and Auxiliary
Power (+).
Make sure that JP5 shorts legs 2 and 3.
Make sure that JP6 shorts legs 1 and 2.
In “General Parameters” screen (section 5.6) the siren is configured as DC
(mark a “+“ under the “D” letter parameter).
3.7 Relay Outputs
The relay can be used for activating external devices (light, CCTV etc.) and
there are several ways to activate it (zone is activated, pressing Relay Code on
keypad, via telephone, and as response to faults/events).
Connect the relay outputs NO/NC/COM to activate the designated device.
To program Relay Code refer to “HUNTER-PRO 32 User Manual”.
To program relay activation time see section 5.5.2 “Output Time”