HUNTER-PRO 32 Intruder Alarm System - Installation Manual
75
5.7.1 System
in ON State
6
ENTR
ENTR
System Response
ENTER/NEXT/END
System ON
ENTER/NEXT/END
9
In this screen you program the system responses to various events and faults
occurring when the system is
ON
:
Mains failure
Low battery
Zone/tamper faults
False code
PSTN fault
When
is pressed in any of the above System Responses screens, the
following parameter bar appears:
SRKOA123HP
++--+----+
Use
and keys to move right/left on the bar.
Each time the cursor stands on a certain parameter letter, this parameter’s full
name will spear for 3 seconds.
Pressing
on a certain parameter letter will access this parameter.
S
Siren
R
Relay
K
Smoke output
O
ON/OFF
A
Alarm
1
Expender1 output
2
Expender2 output
3
Expender3 output
H
Private dialer
P
Report to CMS
5.7.2 System in OFF State
NEXT
6
ENTR
System Response
ENTER/NEXT/END
ENTR
System OFF
ENTER/NEXT/END
9
In this screen you program the system responses to various events and faults
occurring when the system is OFF. All screens similar to those in ON (previous
section).