The HUNTER-PRO 32 incorporates many operating parameters and options.
Some of the system operations depend on the method of programming, and if
one of the parameters is not programmed correctly, the operation depending
on it will not be executed. This chapter describes the failures displayed on the
keypad and their meanings, as well as various problems that may be
encountered due to improper programming, and options for troubleshooting
the failures that might occur due to incorrect installation and/or programming.
7.1 Restoring Master & Technician Codes
For maximum end-user protection and security, it is not possible to program
the system without knowing the Master Code. If for some reason the Master
Code is not available, then follow these steps to access the system:
Open the Control Panel box.
Disconnect Mains AC voltage from the system.
Disconnect the battery.
Wait several seconds and connect the battery.
Wait until the display appears on the keypad unit.
Enter the factory default Master Code (5555).
Program a new Master Code (it is not possible to see the old code).
Connect Mains AC voltage.
Close the Control Panel box.