HUNTER-PRO 32 Intruder Alarm System - Installation Manual
30
3.3.3 I/O-8: External Expenders
A zone and output expansion card connected to the keypad’s communication
lines (BUS). The card has 8 zones and one relay output. It is possible to install
up to three I/O-8 cards (providing an EXP-LOCAL is not installed) in order to
expend the system to 32 zones. Each card has an individual ID number
configured by the jumpers on it (see Drawing 2 and the card itself to determine
ID number).
Card ID No. 1 2 3
JP4
JP3
JP2
Jumper
position
JP1
Table 2- Determining I/O-8 ID number
IMPORTANT!
Two cards cannot have the same ID number.
The cards need be configured in a chronological order and without
missing a number
The card’s ID number determines the number of zones connected
to it (see table 1).
NOTE:
It is recommended to connect the +V to the expansion card,
separately from the control panel.
To connect the I/O-8:
Follow the table below in order to connect the card/s to the control panel’s bus