HUNTER-PRO 32 Intruder Alarm System - Installation Manual
68
check (in case system connected via switch-board/ non
standard PSTN)
L
Checking
line in ON
PSTN checked
every minute
the system is on
L
Checking
line in OFF
PSTN checked
every minute
the system is off
T
Tone
Dialing
“+” For DTMF
“-“ For PULSE
A
Answering
Machine
In case of two rings, hang-up, waiting for 10 seconds
and then another ring, system features line snapping.
NOTE:
Make sure answering machine picks calls after more than two rings
V
Voice Unit A voice-unit is connected to the system
D
Block
Remote-
Charge
Connecting to COMAX via modem is disabled. Possible to
bypass this feature by pressing Master Code and then
ENTER twice.
R
Block
Remote
Disarm
Remotely disarming the system is disabled.
5.5 TIMERS
In this menu all the timers in the system are programmed.
5.5.1 Entry/Exit Delay
4
ENTR ENTR
Timers, Counters
ENTER/NEXT/END
Entry/Exit Delay
ENTER/NEXT/END
In this screen Entry delay 1 and 2 are programmed (see “Zone Programming”
section 5.3 for allocating a delayed zone and its authorization) and the exit
delay: