24 - 02 - 00
Page - 24 - 08
Reissued: August 1, 1986
1I7
CHART 2402. TROUBLESHOOTING (BATTERY) (cont)
Excessive corrosion inside Spillage from overfilling. Use care in adding water.
container.
Vent lines leaking or clog- Repair or clean.
ged.
Charging rate too high. Adjust voltage regulator.
Battery freezes. Discharged battery. Replace.
Water added and battery not Always recharge battery for
charged immediately. one-half hour following
addition of water in freezing
weather.
Battery polarity reversed. Connected backwards on Battery should be slowly dis-
charger. charged completely and then
charged correctly and tested.
Battery consumes excessive Charging rate too high (if in Correct charging rate.
water. all cells).
Cracked jar (one cell only). Replace battery.
Trouble Cause Remedy