EasyManua.ls Logo

Piper Dakota - Inspection of Exhaust System; Exhaust System Inspection Points

Piper Dakota
616 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 78-1. Exhaust System Inspection Points
GENERAL
INSPECTION OF EXHAUST SYSTEM (figure 78-1)
—CAUTION—
All airplanes should be fitted with a new muffler at or near 1000
hours of muffler use.
The entire exhaust system, including heat exchange shroud, muff l e r, muffler baffles, stacks, and all
exhaust connections must be rigidly inspected at each annual or 100 hour inspection. The possibility of exhaust
system failure increases with use. The system must be checked more carefully as the number of hours
increases. The system must also be checked carefully before winter operation when the cabin heat will be in
use.
78 - 01 - 00
Page - 78 - 01
Reissued: August 1, 1986
2K12
PIPER AIRCRAFT
PA-28-236
MAINTENANCE MANUAL