Managing Internal Certificates
R81.10.X Quantum Spark 1500, 1600, 1800, 1900, 2000 Appliances Locally Managed Administration Guide|197
Configuration Workflow
1. Complete the First Time Configuration Wizard on both appliances.
In the Local Network page of the wizard, clear the Enable switch on LAN ports
checkbox.
2. Configure network settings on the appliance that is the primary Cluster Member.
3. Connect cables between the Sync interfaces on the appliances.
Note - You can also connect single physical Sync ports (non-Bond) through a
switch.
4. Configure the primary Cluster Member.
Procedure
a. Connect to the WebUI on the appliance.
b. From the left navigation panel, click Device.
c. In the Advanced section, click the High Availability page.
d. Click Configure Cluster.
The New Cluster Wizard opens.
e. On the page Step 1: Gateway Priority:
i. Select Configure as primary member.
ii. Click Next.
f. On the page Step 2: SIC Settings:
i. In the section Secure Internal Communication, in the fields Password
and Confirm, enter a password for connecting the two Cluster Members to
each other.
Note - You cannot use these characters in a password or shared
secret: { } [ ] ` ~ | ‘ " \ (maximum number of
characters: 255)
ii. Open the section Advanced.
iii. Configure the required settings for the Sync interface (by default, LAN2).
Important - The configuration on the secondary Cluster Member
must match the configuration on the primary Cluster Member.
iv. Click Next.